Automated environmental monitoring
Know changes early.
Stay in control of every decision.
SITECH automated monitoring stations track water and air quality continuously — timely alerts when indicators exceed thresholds, AI-based WQI/AQI forecasting, everything managed in Vietnamese-language software.

Why continuous monitoring is needed
One water sample, one moment in time — not enough.
A single sampling result at a single moment can hardly reflect the full behaviour of a whole river. Automated monitoring adds an important layer of information between sampling rounds: how indicators are changing, when an anomaly began, and which point to check first.
Average PM2.5 in Viet Nam in 2023, versus the WHO recommended level.
of Nhuệ River monitoring points rated poor to very poor, with WQI around 10–25 and more than 2,500 major discharge sources.
Surface-water monitoring points across southern river basins deployed by the Department of Environment in 2025.
Products
One system, for every environment.
Each product line has its own configuration — no single figure is shared across all of them. Choose the right device for the right measuring point.
Surface-water monitoring
- ARM Cortex-M4 180 MHz
- Error under 5%
- 30-day backup power
- AI-based WQI forecasting
Groundwater & water supply
- Automatic pipe-burst alerts
- Meters verified / calibrated by the competent authority
- LoRa Node: 3 AA batteries, 3–5 years
- Remote data export
Air monitoring
- ARM Cortex-M4 80 MHz
- Error under 5%
- AI-based AQI forecasting
- Pole-mounted, compact
Dust monitor
- Error under 10%
- On-site LCD screen + GPS + heater
- 3-day backup power
- Mobile monitoring
Aquaculture
- Automatic actuator control following the production process
- ARM Cortex-M4 48 MHz
- Solar-powered, safe over ponds
- 30-day backup power
Agriculture
- Automatic actuator control following the production process
- 3G/4G or LoRaWAN
- Customised for each crop type
- 30-day backup power
Monitoring software
Data doesn’t sit in a filing cabinet.
It sits on your screen.
Green Solution software comprises 3 tools: a public information portal for residents and businesses, a mobile app (iOS, Android) and internal operations software for regulators.
- Station list, distribution map, pollution rankings — colour codes from green (no pollution) to brown (most severe pollution)
- Hourly or daily charts; readings above the safety threshold shown in red
- Alerts via website, mobile app and SMS when an indicator changes abnormally
- Access permissions by user role
- Remote operation: change measurement/sending frequency, change alert thresholds, clean sensors (surface-water line)

AI forecasting
WQI / AQI forecasting — to prepare, not to guess.
The system analyses historical monitoring data to forecast water quality (WQI) and air quality (AQI) trends at each measuring point — supporting alert preparation, activity planning and response plans based on expected trends. WQI calculation and publication follow the method and parameter set in QCVN 08:2023/BTNMT and Decision 1460/QĐ-TCMT (VN_WQI).
Water quality forecasting. Already applied at the Hội An water monitoring station.
Air quality forecasting for air stations and dust monitors.
Forecast scope, horizon and accuracy depend on the data and model validation results at each point. AI supports managers; it does not replace on-site verification.
Why choose SITECH
One point of contact. From sensor to decision.
One point of contact
Hardware, software and AI from one provider — no stitching together multiple vendors.
Technology ownership
Over 50% localisation; software developed 100% in Viet Nam. In-country resources for maintenance, repair and upgrades.
In-country support
1-year system warranty (sensors per manufacturer). Engineers support maintenance and operation.
Customised to requirements
Change monitoring parameters, alert thresholds and add new features to match the user’s actual needs.
Deployed
Operating at these locations.
List of installed monitoring stations. With you from survey to operation.
- Đà Nẵng City Administrative Centre
- Hòa Cầm traffic junction
- Office building, 213 Nguyễn Tất Thành, Đà Nẵng
- Hội An Ancient Town Conservation Centre
- Sao Bắc Đẩu Technology JSC, Tân Thuận Export Processing Zone, Ho Chi Minh City
- Quang Trung Software City (QTSC), Ho Chi Minh City
Process
A Standard Process.
Survey & Needs Analysis
Survey the site or operating process, review available data, agree measurable objectives.
Solution Design & Consulting
Design the solution architecture — sensors or models — agreeing scope, data and acceptance criteria before deployment.
Deployment & Integration
Install, configure and integrate with existing systems; test, calibrate and hand over with operating instructions.
Operation & Continuous Improvement
Monitor, maintain, calibrate periodically, update models from real data.
Frequently asked questions
Straight questions, honest answers.
Does an automated station replace manual sampling?
No. An automated station supports continuous tracking; it does not automatically replace all sampling and analysis required by regulation. It adds a layer of information between sampling rounds — and when data is used for specialist reporting or official publication, the monitoring method must be defined in advance and data quality assured as required.
How accurate is AI forecasting?
Forecast scope, horizon and accuracy depend on the data and model validation results at each monitoring point. SITECH agrees the application approach with the user according to specific conditions. AI supports managers; it does not replace on-site verification.
What if power or network is lost?
The main product lines have backup power for up to 30 days without sunshine (dust monitor: 3 days). The system can back up and preserve data on power loss.
Will our data be made public?
No. The public information portal only publishes data measured, verified and approved for publication by state agencies. A unit’s operational data is access-controlled by user role.
Where can a station be installed?
The installation site needs coverage (3G/4G, LoRa or WiFi depending on the line). For surface-water stations, coverage, buoy anchoring, flood risk, and sensor cleaning and calibration arrangements must be assessed. SITECH surveys before installation.
What about warranty and maintenance?
SITECH provides a 1-year system warranty; sensors follow the manufacturer’s warranty policy. In-country resources for maintenance, repair and upgrades.